Plugs, Clamps & Misc. Printer Friendly Version
     
  plugs, clamps & misc.
 
  1. Pipe Repair Plugs
  2. Exchanger Plugs for 2", 2 1/2" and 3"tubes - custom sizes
  3. Restriction Adapters (Gage Adapters) and Connectors
  4. Pipe Repair Clamps - for temporary repair of pipe

  5. Also:
  6. Sample Shovels
  7. Catch basins
  8. Pin bars
  9. Wedges
  10. Chisels
  11. Custom control panels
  12. Weld bosses
  13. Wind cone hardware
       
    Threaded Pipe Repair Plug  
    threaded pipe repair plug  
   
Plugs to be machined from Hex. Bar Stock of SAE C1018 Steel. Pack harden plugs,
followed by drawing at a temperature which will relieve the plugs of brittleness
and still leave them hard enough to thread themselves into the wall of steel pipe.

 
   
Hex Size A DIA B C D E DIA
1/2"   3/8"   3/8"   1"   1 1/2"   1/8"  
11/16"   5/8"   3/8"   1 7/8"   2 3/8"   1/8"  
7/8"   13/16"   1/2"   2 5/8"   3 1/4"   1/8"  
1 1/2"   1 7/16"   7/8"   4 1/2"   5 1/2"   3/16"  
2"   1 15/16"   7/8"   6"   7"   1/4"  
 
    Case hardened tempered .005 to .010 Deep.
50 to 60 Rockwell.
 
       
   
Detail of Exchanger and Cooler Repair Plugs plugs
repair plugs
Material as specified
 
   
Mark A C D Taper
per ft.
Taper
Angle
Tube
Size
1 1-5/8" 9/16" 21/32" 23/32" 1° 41'-15" 3/4"
2 1-5/8" 19/32" 11/16" 23/32" 1° 41'-15" 3/4"
3 1-5/8" 21/32" 3/4" 23/32" 1° 41'-15" 3/4"
4 2-1/2" 11/16" 7/8" 29/32" 2° 9'-46" 1"
5 1-5/8" 15/32" 9/16 29/32" 1° 41'-15" 3/4"
6 3" .648 .773 1/4"   3/4"
 

Mark 1 to be used in 14 ga tubes.
Mark 2 to be used in 16 ga tubes.
Mark 3 to be used in 16 ga tubes oversize.
Mark 4 to be used in 12 ga tubes.
Mark 5 to be used in 11 ga tubes.
Mark 6 to be used in 20 ga tubes.

 

 
   

Pipe Repair Clamps for temporary repair of pipes
For 1" pipe to 12" pipe
2 bolt or 4 bolt
pipe repair clamp &nbs p;
  Notes
1. Emergency pipe clamps are intended for temporary repair of failed pipe.
2. Bar Material shall meet ASTM A-7 specifications.
3. All clamps up to 4" nominal pipe size inclusive, shall have two bolts, as shown; all clamps over 4" nominal pipe size shall have four bolts. Unless otherwise specified on the order, the supplier shall furnish all clamps completely assembled with nuts and bolts.
4. Bolts and nuts shall be of commercial quality. Bolts shall have square heads and meet ASTM A 306 class 50, 55 or 60.
Nuts shall be A.S.A. Heavy Series, semi-finished, machined from bar stock are not acceptable. All threading shall conform to the A.S.A. (National) Coarse Thread Series, class 3 fit.
 
 
       
   
All dimensions in inches.
Mark
No
Nominal
Pipe Size
A B C D E* F R S BAR Weight
Lbs.per Pair
I 1 11/16 3/16 1 1/2 4 1/2 9/16 3/4 1/4 1/2 x 1 1/2 2 x 1/4 x 5 1/4 1.3
II 1 1/2 1 3/16 2 5 1/2 9/16 3/4 3/8 1/2 x 1 1/2 2 1/2 x 1/4 x 6 1/2 2.3
III 2 1 3/16 1/4 2 5/16 6 1/8 9/16 3/4 1/2 1/2 x 2 2 1/2 x 3/8 x 7 3.7
IV 2 1/2 1 1/2 1/4 2 7/8 7 3/4 11/16 1 1/2 5/8 x 2 1/2 2 1/2 x 3/8 x 8 1/2 4.6
V 3 1 3/4 3/8 3 1/8 8 1/4 11/16 1 3/4 5/8 x 2 1/2 3 x 1/2 x 9 1/2 8.0
VI 4 2 1/4 3/8 3 3/4 9 1/2 11/16 1 3/4 5/8 x 2 1/2 3 x 1/2 x 11 9.4
VII 6 3 5/16 3/8 5 12 11/16 1 3/4 5/8 x 2 1/2 4 x 1/2 x 15 18.1
VIII 8 4 5/16 1/2 6 14 1/4 13/16 1 1/8 3/4 3/4 x 2 3/4 4 x 1/2 x 17 1/2 19.8
IX 10 5 3/8 1/2 7 16 1/4 13/16 1 1/8 3/4 3/4 x 2 3/4 4 x 1/2 x 20 1/2 23.2
X 12 6 3/8 5/8 8 1/8 18 1/2 13/16 1 1/8 3/4 3/4 x 2 3/4 4 x 1/2 x 24 1/2 27.8
 
* Bolts holes may be punched.
 
   

Restriction Adapters (Gage Adapters) and Connectors

  1/2" FNPT x 3/3" MNPT
1/2" MNPT x 3/4" MNPT
3/4" MNPT x 3/4" MNPT
restriction adapters and connectors
   
restriction adapters and connectors restriction adapters and connectors
DET 1 DET 2
Restriction Adapter
3/4" MNPT X 1/2" FNPT
Restriction Nipple
3/4" MNPT X 3/4" MNPT
3/4" MNPT X 1/2" MNPT
restriction adapters and connectors  
DET 4  
Gage Adapter
3/4" MNPT X 1/2" FNPT
 
 
    Top